ruggedized special protected MADI cables
(in and outdoor use)
"Live is tough"
|
|
Live and outdoor demands for digital multichannel audio are
growing every day. MADI gains a foothold as an easy to use hum
free universal and versatile interface to span huge distances
with no loss in quality here as well. But with all its advantages
it also brings one major new obstacle!
The mechanical vulnerability of its fiber optical cables! Unlike
in most analogue systems, a small damage results here always
in a total blackout.
Other than in fixed installations, the cables are here unprotected
and exposed to all sorts of mechanical threats like stairs,
corners, flightcase-wheels or just being stepped on or bent
by a careless crew member. Especially for these demands madicables.com
offers ruggadized fiber optical cables, that are specially protected
against those daily occuring mechanical threats "on the
road".
We call them:
|
|
"Live MADI Cables"
(military
standard)
|
•
Abrasion • Chemical Exposure • Crush •
Dust/Debris |
•
Impact • Vibration • Tension • UV Exposure
|
|
•
Flexing • Electrostatic Discharge(ESD) • EMI/RFI
Exposure • Temperature Extremes |
•Moisture/Humidity/Water
•Physical Abuse
• Electrical Fast Transients (EFT)
|
|
|
|
|
Our Live core 2 cable features
100 kpsi proof-tested fiber, a primary buffer of UV-cured acrylate
material to a diameter of 500 μm and a secondary hard elastomeric
buffer to 900 μm diameter. This provides the ultimate environmental
and mechanical protection and is identical to the buffering
on military tactical cables. It can withstand any flightcase,
a truck or even a tank running over it and works under all possible
imaginable scenarios in digital audio.
|
standard length:
|
1
, 2 , 3 , 5 , 7 , 10, 20 , 50 , 80 , 100 meters
(other length on demand) |
Jacket Ø [mm]
|
|
Single fiber cable Ø [mm]
|
2.0 |
Tight tube Ø [mm]
|
0.9 |
Approx. weight [kg/km]
|
31 |
Max. allowable tensile load [N]
|
due to IEC 60794-1-2
E1 |
550 in service
(r > 110mm) |
2200 during
installation (r > 90mm) |
Min. Bending radius [mm]
|
52mm in service
|
104mm during
installation |
Crush resistance [N/cm]
|
due to TIA/EIA-455-41, Military
Req. |
440 N/cm |
Impact resistance [Impacts]
|
due to EIA/TIAQ-455-25
Military Req. |
200
impacts |
Flex Rsistance
|
2,000 cycles |
Torsion resistance [Rotations]
|
due to IEC 60794-1-2
E7 |
3 cycles
( L=1m,, –40°C ±4) |
Attenuation
|
3.0 dB/km
|
Temperature range [°C]
|
dur to IEC 61300-2-22 |
-55°C to +85°C
during installation |
-55°C to +85°C
in service |
| -70°C to +85°C
in storage |
Fire load [MJ/m]
|
0.8 |
| |
These